What Should You Consider when Buying a Laboratory Autoclave

What Should You Consider when Buying a Laboratory Autoclave?

PT 100 Sensor

There is a significant difference between the sterilization load and the chamber of the heating time when sterilizing liquids. And the former being significantly slower than the latter of the heating time. The chamber temperature reaches sterilization conditions earlier than the liquid. For example, the chamber temperature reaches 121°C and begin starting the sterilization stage. However, the liquid has not reached the sterilization temperature. Therefore, the sterilization process will be ineffective. Two PT100 sensors are placed in the liquid to ensure that the sterilization stage begins only when the liquid reaches the sterilization temperature. In autoclave that sterilize solids, the sensor is usually located near the drain. What should you consider when buying a laboratory autoclave, Huanyu tells you what you need to pay attention to.

Sterilization Glassware and Hollow Instruments

It is essential to remove air prior to sterilization in order to maximize steam penetration when sterilizing glassware, hollow parts, and pipette nozzles. These sterilization loads inherently contain air inside the container which must be removed to ensure complete sterilization of the sterilization loads. Using a vacuum pump, even more than 99% of the air can be removed by pre-pumping the vacuum pulse. Vacuum pumps can also quickly extract vaporized water by keeping the sterilization load dry more efficiently by maintaining a lower pressure.

How does Active Cooling Work?

Increase chamber pressure by forcing compressed air through the filter into the chamber after the sterilization stage.It can prevent boiling, spillage, or cracks in the vessel that may occur under low pressure conditions by increasing chamber pressure. Cold water circulates through coils around the chamber at this stage.The liquid load is cooled quickly and safely, saving time and protecting the sterilizing medium from excessive boiling via the circulation of cold water and compressed air.Ultra-rapid cooling is combined with rapid cooling through the use of a radial ventilator. It transfers heat from the load to the relatively cool chamber walls, cooling the sterilization load more quickly by circulating air inside the chamber.

What Should You Consider when Buying a Laboratory Autoclave

How does F0 Work?

There are two ways to apply the F0 cycle:

The calculated heating time is included in the total sterilization time start from the 105℃.It does not reduce the total cycle time accordingly that the first option calculate the total value of F0.It tracks and reports the F0 value only at the end of the cycle.The second option will adjust the sterilization holding time according to the F0 value, which depends on different variables, including sterilization load.This option reduces the sterilization holding time based on the F0 value.It can save time ans avoid over-boiling the sterilization liquid while ensuring proper sterilization by calculating in minutes.

F0 Autoclave Circulation of Thermosensitive Liquid Media:

The laboratory autoclave performs the F0 cycle. This function reduces the exposure time of the sterilization load to high temperatures. This is especially important when sterilizing sensitive thermal liquid media.It can maintain sterilization load integrity and reduce the total cycle time by minimizing the amount of time the liquid media is exposed to high temperatures. F 0’s theory is that microorganisms and bacteria can be destroyed before reaching the sterilization temperature (for example, 121°C). Therefore, actual sterilization can begin before reaching the sterilization temperature. Sterilization will start when the sterilization load reaches the sterilization temperature is the main purpose of the F0 cycle.

How do biohazard filters work?

Air in the chamber is filtered through microbiological filters for harmful substances during the air removal and heating stage before sterilization. HEPA filters are used to prevent the passage of microorganisms found in autoclave wastewater. The destruction of pathogens captured in the filter not only eliminates the pathogen and maintains sterile conditions in the surrounding laboratory. But also provides safe sterile conditions for subsequent autoclave cycles.

Waste Sterilization with a Biohazard Filter:

Does your laboratory use biohazard media? The air discharged from the autoclave may contain infectious materials, which may be contaminated with toxins, viruses, or medical waste. There must be an appropriate sterilization solution to protect the laboratory environment from this potentially harmful air pollution. Since biohazard media put the people who handle them and the laboratory environment at risk. Therefore, it is highly recommended to equip autoclaves with advanced air filters.